• Powered Turntable Acc.

    The Powered Turntable is used when two parallel conveyor lines must be close together with a 180° turn at one (or bth) ends. The turning radius is held to a minimum, less than would be available with gravity or powered curve sections. Turntable Plow and Guard Rails insure product safety while negotiating 180° fpm.

    Capacity – 500 lb total distributed load - maximum unit load - 150 lb.
    Adjustment – 28" to 40" adjustable top of table.

  • 251CRR - Powered Turntable

    Capacity – Model 251CRR chain driven live roller mounted to the top of the table, designed for handling up to 4000 lb pallets.
    Normal operation – 90 degree or 180 degree indexing.
    Turntable – Motor driven.
    Floor supports – Heavy duty supports, with minimum elevation of 20" to top of roller.

  • Plows - Manual and Pneumatic

    Plow arm – 5 1/2" x 2" x 7 gauge.
    Plow angle – 30° or 45°.

  • Air Operated Blade/Roller Stop

    Air Operated Stops are used where automatic line control is required such as assembly work stations, shipping areas, etc. Can be mounted to underside of models 138SR, 190SR, 20SR, 190CAP, 138CAP, 190ZPA.

    Capacity – Blade - 150 lb, 1 3/8" roller - 50 lb, 1.9" diameter roller - 150 lb. All are live load capacities at 60 fpm.
    Bearings – High capacity (2) bolt flange bearings.
    Stop – 1 3/8" diameter x 18 gauge unplated steel roller for 1 3/8" conveyors. 1.9" diameter x 16 gauge galvanized steel roller for 1.9" x 2.0" conveyors.
    Blade – 1/4" steel plate.
    Position – Supplied normally down. Can be supplied normally up-specify.
    Air cylinder – 1 1/4" bore x 2" stroke double acting air czlinder to raise or lower stop.
    Air requirements – Minimum pressure 60 psi, maximum 100 psi. Free air consumption at 60 psi - .014 cu. ft. per cycle, at 100 psi - .022 cu. ft.
    Valve – Single solenoid 4 way valve. 1/4" spring return - 20 NPT valve ports.
    Electrical requirements – 120 V, single phase, 60 Hz. Current draw - .068 amps or 24 VDC.

    Installation note: To eliminate contaminants in air supply line, a filter, regulator (FR) should be installed prior to valve.

  • Hand Operated Blade/Roller Stop

    Hand Operated Stops are used where manual line control is required such as assembly work stations, shipping areas etc. Can be mounted to underside of models 138SR, 190SR, 20SR, 190CAp, 138CAP and 190ZPA.

    Capacity – Blade - 150 lb, 1 3/8" diameter roller - 50 lb, 1.9" dimater roller - 150 lb. All are live capacities at 60 fpm.
    Bearings – High capacity (2) bolt flange bearings.
    Operation – Hand operated lever to raise or lower stop can be used in normally up or down positions.
    Blade – 7 gauge formed angle 1" x 1 1/2" for 1 3/8" conveyors - 1 1/2" for 1.9" and 2.0" conveyors.
    Roller – 1 3/8" diameter x 18 gauge galvanized steel roller for 1 3/8" conveyors. 1.9" diameter x 16 gauge galvanized steel roller for 1.9" and 2.0" conveyors.
    Stroke – 2" above rollers.

  • Foot Operated Blade/Roller Stop

    Foot Operated Stops are used where "hands free" manual line control is required such as assembly work stations, shipping etc. Can be mounted to underside of models 138SR, 190SR, 20SR, 190CAP, 138CAP and 190ZPA.

    Capacity – Blade - 75 lb, 1 3/8" diameter roller - 50 lb, 1.9" dimater roller - 150 lb. All are live capacities at 60 fpm.
    Operation – Food operated lever to lower stop. Spring return to up position.
    Stop – Blade - 1/4" steel plate - roller 1 3/8" diameter x 18 gauge galvanized steel roller for 1 3/8" conveyors. 1.9" diameter x 16 gauge galvanized steel roller for 1.9" x 2.0" conveyors.
    Position – Supplied normally up. Can be supplied normally down - specify.
    Stroke – 1 1/2" above roller.

  • Air Operated Chain Transfer

    Chain – Two strands of #60 high side bar roller chain; min. 10" chain centers.
    Mounting – Designed to install in standard "251CRR" frames.
    Cycles – Up to 4 cycles per minute.
    Air requirements – Min. pressure 60 psi, max. pressure 125 psi. Free air consumption at 60 psi .035 cu. ft. per cycle.
    Electrical requirements – 120 V, single phase, 60 Hz. Current draw - .07 amps or 24 VDC.
    Electrical controls – None furnished as standard.

    Installation note: To eliminate contaminants in air supply line, a filter, regulator (FR) should be installed prior to valve.

  • Auto-Sort Air Operated Wheel Diverter

    Package size – Min. 6" wide x 9' long, max. 25" wide x 36' long.
    Cycles – Up to 40 times per minute.
    Mounting – Mounts in "190LS" conveyor. Being modular in design, it can be located almost anywhere in length of conveyor. Specify right hand or left hand operation.
    Diverting wheels – Consists of a double row of 3" diameter wheels spaced proportionately across conveyor width. Driven by high capacity poly belts by it's own drive. May also be slave driven consult factory.
    Supports – Minimum elevation 21". Specify height conveyor will be installed.
    Air cylinder – 2" bore x 1" stroke double acting.
    Air requirements – Min. pressure 60 psi, maximum 125 psi. Free air consumption at 60 psi - .018 cu. ft. per cycle.
    Valve – Single solenoid 4 way valve. 1/4" - 20 NPT valve ports.
    Electrical requirements – 120 V, single phase, 60 Hz, current draw .07 amps or 24 VDC.
    Speed reducer – Heavy duty worm gear, C-face.
    Electrical controls – Not furnished as standard equipment.

    Installation note: To eliminate contaminants in air supply line, a filter, regulator (FR) should be installed prior to valve.

  • Turning Wheel

    Attachment – Brackets for attaching to all conveyors, specify model.

  • Traffic Controller

    Used to control product flow from two conveyor lines into a converging point. It prevents both lines from feeding into the converging point at same time. When an item contacts one arm it immediately locks out the opposite arm. When the product is clear, the arm returns to its normal position.

    Capacity – 75 lb impact capacity at 60 fpm; 250 lb accumulated capacity.
    Minimum weight – 10 lb minimum package weight required to operate arms.
    Application – Available for 30°, 45°, 90° or 180° operation - specify.

  • High Speed Push-Off

    Used for 90° transfers when package specifications allow product to be pushed from side. Can also be used to divert packages from one lane to another in parallel conveyors lanes.

    Cycles – Up to 40 times per minute, up to 24" stroke only, at 80 psi.
    Air cylinder – 2" bore double actinf, automatic return, with jam protection.
    Air requirements – Minimum pressure 60 psi; maximum 125 psi. Free air consumption at 60 psi - .235 cu. ft. per cycle for 20" stroke, .355 cu. ft. for 30" stroke.
    Valve – Single solenoid 4 way, automatic return valve, 1/2" - NPT valve ports; filter-regulator included.
    Electrical requirements – 120 V, single phase, 60 Hz. Current draw .07 amps.
    Electrical controls – PLC included.

  • Guard Rails

    Adjustable channel